Thermal Energy Storage Molten Salt


Molten salts (including heat-conducting salts and thermal media) are inorganic salts melted into a heat-transfer medium. They are molten bodies composed of metal cations and non-metal anions. At standard temperature and atmospheric pressure they are solid; when heated, they become liquid salts.
1. Product Name:Energy storage molten salt

Item
melting point
boiling point
Heat of Fusion
Specific Heat
Average Thermal Conductivity
Operating Temperature
Appearance
Specification
142℃-148℃
680℃
18Kcal/Kg
0.34 kcal/Kg·℃
0.317
150℃-550℃
Pale-yellow crystals or granules

2. Instructions for Use
Put the thermally conductive molten salt into the tank and heat it directly to melt it, or add a small amount of water to the thermally conductive molten salt and heat it to melt it. After melting to a sufficient viscosity, it can be circulated with a circulation pump, and then sent to a heat-carrying furnace to gradually increase the temperature in a cycle to reach the target temperature.
3. Things to note
① Molten salt should be kept clean and should not come into contact with organic matter such as carbon, rosin or reducing substances to avoid causing violent chemical reactions. 
② When starting to heat up, strictly control the heating rate and try to avoid rapid cooling and heating during system operation. 
③ The flow rate is constant during circulating heating and cannot exceed the film temperature. 
④ When using at high temperatures, it is strictly forbidden to mix water and organic substances. 
⑤ When the temperature of commonly used molten salt exceeds 550℃, the molten salt becomes unstable, reacts, releases gas, and the melting point of the molten salt increases, causing the molten salt to deteriorate. 
⑥ When there is a lot of sediment in the molten salt of the heat carrier, the molten salt should be replaced.
⑦ Before stopping, all the molten salt must be poured back into the molten salt storage tank, and then the shutdown procedure can be entered.